Skip to main content

Water Vapor Permeation Analyzer W3/030

W3/030 Water Vapor Permeation Analyzer is for the water vapor permeation rate measurement of plastic films, laminated films, sheets as well as various materials used in medical and construction industries. Through water vapor permeation rate testing, the demands for control and adjust technical indexes and satisfy.

This instrument confroms to the followting standards:
ASTM E96: Standard Test Methods for Water Vapor Transmission of Materials
ASTM D1653: Standard Test Methods for Water Vapor Transmission of Organic Coating Films
ISO 2528: Sheet materials -- Determination of water vapour transmission rate -- Gravimetric (dish) method
TAPPI T464: Water Vapor Transmission Rate of Paper and Paperboard at High Temperature and Humidity


Water Vapor Permeation Analyzer W3/030

Water Vapor Permeation Analyzer Principle
A specific humidity difference is formed among the two sides of the specimen under a certain temperature. The water vapor permeates through the specimen and into the dry side. By measuring the weight changes of the cup, water vapor transmission rate and other parameters can be obtained.

Water Vapor Permeation Analyzer Technical Specifications
Test Range: 0.1~10,000 g/m2•24h (Routine)
Accuracy : 0.01 g/m2•24h
Test Temperature: 15°C ~ 55°C (Routine)
Temperature Accuracy: ± 0.1°C
Test Humidity: 10% RH~98% RH(Standard 90% RH)
Humidity Accuracy : ±1%RH
Purge Velocity: 0.5~2.5 m/s   (Note: non-standard purge velocity can be customized.)
Test Area: 33 cm2 ×3
Numbers of Specimen: 3 Pieces
Specimen Thickness: ≤3mm  (Note: demands for other thicknesses can be customized.)
Specimen Size: φ74 mm
Test Chamber Volume: 15L
Gas Source: air
Gas Source Pressure: 0.6MPa
Inlet Size: φ4mm polyurethane pipe

Contact us for more detail information via Labthinkchina@gmail.com

Comments

  1. I read your blogs like every week. Your humoristic style is awesome, keep up the good work!Thanks for sharing such beneficial information with us.

    Micro Filtration | Ultra Filtration

    ReplyDelete

Post a Comment

Popular posts from this blog

Quality Requirements of Lithium Ion Battery Separators

Business Challenge Lithium-ion batteries have one of the best energy-to-weight ratios, no memory effect, and a slow loss of charge when not in use. This makes them one of the most popular types of batteries for portable consumer electronics in today’s marketplace. Lithium-ion batteries can be found in cameras, laptops, power tools, toys and more. However, as recent well-publicized recalls demonstrate, they can pose a risk of fire and overheating. In addition, they can suffer from a reduced lifespan if not properly treated. As a result, new and stricter requirements are being implemented globally to address potential hazards, leaving manufacturers and purchasers of products containing lithium-ion batteries to meet increasing requirements and overcome safety concerns. Lithium Ion Battery Separators A Lithium Ion battery Separator is a permeable membrane placed between the anode and cathode of a battery. The main function of a separator is to keep the positive and negative electr...

Comparative Analysis of Aluminum-Coated VMPET and VMBOPP Oxygen Transmission Properties

Aluminum-coated films offer a cost-effective alternative to pure aluminum foil for packaging applications requiring good barrier properties. However, the effectiveness of these films can vary depending on the substrate material used. This study investigates the Oxygen Transmission Rate (OTR) of VMPET (vapor-deposited aluminum on PET) and VMBOPP (vapor-deposited aluminum on BOPP) to assess the influence of the substrate on barrier performance. The OTR test employed the coulometric method (equal pressure) following the standard ASTM D3985. This method utilizes a controlled environment chamber to measure the rate of oxygen permeation through the film sample. Labthink C230H Oxygen Transmission Rate Test System was used for this study. This instrument is designed and manufactured based on the coulometric sensor method (aka. equal pressure method) and conforms to ASTM D3985. This instrument can be used to measure the oxygen transmission rate of barrier materials with high and medium barrier ...

Introducing Vacuum Decay Testing Method for Pharmaceutical Packaging Integrity

Maintaining the integrity of pharmaceutical packaging is fundamentally essential for safeguarding product efficacy and patient safety, and vacuum decay testing stands as a highly reliable non-destructive method for verifying this integrity. This technique, particularly effective for blister packs, vials, and pre-filled syringes, identifies leaks without compromising product sterility or efficacy. Vacuum decay testing leverages the principle that a sealed package, when subjected to a vacuum, will exhibit predictable pressure changes if it's leak-free. Conversely, a leaking package will show a different pressure profile. Specific Vacuum Decay Techniques:   Differential Pressure Transducers: These precise sensors measure the difference in pressure between the vacuum chamber and a reference chamber. This allows for detection of very small leaks. Absolute Pressure Sensors: These sensors measure the absolute pressure within the vacuum chamber, providing data to determine the rate of pres...