Barrier Properties Assessment of Packaging for Oxygen-Sensitive Medical Diagnostic Kits

Medical diagnostic kits containing oxygen-sensitive components necessitate packaging with robust moisture and oxygen barriers to ensure the accuracy and reliability of their diagnostic tools. Oxygen and moisture can degrade sensitive reagents and sensors, leading to inaccurate results. Materials such as barrier foil laminates, flexible barrier films, foil pouches, rigid plastics (HDPE, LDPE, PP, PS), and glass vials or ampoules are commonly employed.

To maintain product integrity, packaging for these kits must incorporate features like tamper-evident seals, easy-peel designs, and durable construction, especially when protecting sensitive electronic components. To verify these properties, packaging materials undergo rigorous testing.

Oxygen permeation testing measures the rate at which oxygen passes through the packaging, crucial for oxygen-sensitive components, while moisture vapor transmission rate testing determines the material's resistance to moisture ingress.


Labthink C406H Oxygen /Water Vapor Transmission Rate Test System is based on the testing principle of Coulometric oxygen sensor and infrared water vapor sensor. It is designed and manufactured according to ASTM D3985、ASTM F1249,ISO 15106-2 and other relevant standards to provide high precision and high efficiency oxygen and water vapor transmission rate tests for high and medium gas barrier materials. It is suitable for testing the oxygen and water vapor transmission performance of films, sheets and related materials in the fields of food, medicine, medical devices, daily chemicals, photovoltaic, electronic and many others.

The sterile barrier integrity and the physical performance are thoroughly evaluated as well. For instance, tensile strength and elongation tests assess the material's ability to withstand stretching and pulling.

By conducting these comprehensive tests, manufacturers can confidently ensure that the packaging safeguards the medical oxygen diagnostic kits, preserving their safety and performance throughout their intended shelf life.

Comments

Popular posts from this blog

Quality Requirements of Lithium Ion Battery Separators

Business Challenge Lithium-ion batteries have one of the best energy-to-weight ratios, no memory effect, and a slow loss of charge when not in use. This makes them one of the most popular types of batteries for portable consumer electronics in today’s marketplace. Lithium-ion batteries can be found in cameras, laptops, power tools, toys and more. However, as recent well-publicized recalls demonstrate, they can pose a risk of fire and overheating. In addition, they can suffer from a reduced lifespan if not properly treated. As a result, new and stricter requirements are being implemented globally to address potential hazards, leaving manufacturers and purchasers of products containing lithium-ion batteries to meet increasing requirements and overcome safety concerns. Lithium Ion Battery Separators A Lithium Ion battery Separator is a permeable membrane placed between the anode and cathode of a battery. The main function of a separator is to keep the positive and negative electr...

Comparative Analysis of Aluminum-Coated VMPET and VMBOPP Oxygen Transmission Properties

Aluminum-coated films offer a cost-effective alternative to pure aluminum foil for packaging applications requiring good barrier properties. However, the effectiveness of these films can vary depending on the substrate material used. This study investigates the Oxygen Transmission Rate (OTR) of VMPET (vapor-deposited aluminum on PET) and VMBOPP (vapor-deposited aluminum on BOPP) to assess the influence of the substrate on barrier performance. The OTR test employed the coulometric method (equal pressure) following the standard ASTM D3985. This method utilizes a controlled environment chamber to measure the rate of oxygen permeation through the film sample. Labthink C230H Oxygen Transmission Rate Test System was used for this study. This instrument is designed and manufactured based on the coulometric sensor method (aka. equal pressure method) and conforms to ASTM D3985. This instrument can be used to measure the oxygen transmission rate of barrier materials with high and medium barrier ...

Introducing Vacuum Decay Testing Method for Pharmaceutical Packaging Integrity

Maintaining the integrity of pharmaceutical packaging is fundamentally essential for safeguarding product efficacy and patient safety, and vacuum decay testing stands as a highly reliable non-destructive method for verifying this integrity. This technique, particularly effective for blister packs, vials, and pre-filled syringes, identifies leaks without compromising product sterility or efficacy. Vacuum decay testing leverages the principle that a sealed package, when subjected to a vacuum, will exhibit predictable pressure changes if it's leak-free. Conversely, a leaking package will show a different pressure profile. Specific Vacuum Decay Techniques:   Differential Pressure Transducers: These precise sensors measure the difference in pressure between the vacuum chamber and a reference chamber. This allows for detection of very small leaks. Absolute Pressure Sensors: These sensors measure the absolute pressure within the vacuum chamber, providing data to determine the rate of pres...